The structure.TSensor[1] trace ranges from 293.15 to 297.148 across 101 saved checkpoints. It begins at 293.15 and finishes at 297.122 after 100,000 s of test time. The reference export does not state a verified engineering unit for this value. Use its native scale when comparing another run of the same model.
The system being tested
The largest change in structure.TSensor[1] between saved samples lies between simulation times 0 s and 1,000 s. The channel moves from 293.15 to 296.592 across that interval. A finer export is needed to resolve what happens between those observations.
The reference file contains 2 recorded variables. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.
Compare the recorded channels
At 1,000 s, structure.TSensor[1] reads 296.592 and heating.QHeaSys reads 2,000 W. Across the run, the second channel ranges from 0 W to 2,000 W. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.
Reproduce the calculation
The largest absolute change between consecutive stored points appears from 0 to 1,000 seconds. Subtracting 293.15 from 296.592 gives 3.442 source units. Its location brackets the change within one saved interval of 1,000 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | structure.TSensor[1] (source units) | heating.QHeaSys (W) |
|---|---|---|
0 | 293.15 | 2000 |
1000 | 296.5923 | 2000 |
20000 | 297.0544 | 2000 |
40000 | 296.9471 | 2000 |
60000 | 296.8256 | 2000 |
80000 | 296.6777 | 2000 |
86000 | 297.1479 | 2000 |
100000 | 297.1224 | 2000 |
What to check on site
Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Units in the source model
The component declarations identify the scale of the exported variables. In this run, heating.QHeaSys uses W. Keep the exact channel name and unit together when exporting data to a historian. Read the component definition.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.

![And test for ideal heating with radiators. structure.TSensor[1] (source units) ranges from 293.15 to 297.15 across the recorded simulation time (s) interval of 0 to 1e+05. Bands show the minimum and maximum per group of samples. Crossbars mark the median.](/story-art/0b7ef5d279b5c63b3.webp)