The pla.THeaWatSup.T trace covers 20 to 60 °C, a temperature span of 40 K. The first recorded maximum occurs at 3,028,320 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named AllElectricCWStorage. The source file places it under DHC, Plants, Combined. We used the 101 stored values for pla.THeaWatSup.T over the interval 3,024,000 to 3,456,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name pla (All Electric CW Storage), TChiWatSupSet (Constant), THeaWatSupSet (Constant), dpHeaWatSet_max (Constant). The source declares TSetDisSupHea = 273.15+60, TSetDisSupCoo = 273.15+6. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel pla.TChiWatSup.T covers 279.15 to 293.15 K. At 3,028,320 s, the primary value is 333.15 and the companion is 279.15. Their signed difference is 54 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

All-electric plant model with buildings loads. The simulated pla.THeaWatSup.T channel runs from 293.15 to 333.15 K over 432,000 seconds.
All-electric plant model with buildings loads. The simulated pla.THeaWatSup.T channel runs from 293.15 to 333.15 K over 432,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 3,024,000 to 3,028,320 seconds. Subtracting 293.15 from 333.15 gives 40 K. Its location brackets the change within one saved interval of 4,320 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

pla.THeaWatSup.T (K)

pla.TChiWatSup.T (K)

3024000

293.15

293.15

3028320

333.15

279.15

3110400

333.15

279.15

3196800

333.15

279.15

3283200

333.15

279.15

3369600

333.15

279.15

3456000

333.15

279.15

What to check on site

Identify the stored quantity and the boundary through which energy or mass enters. A layer temperature, outlet temperature and volume mean describe different states. Preserve initial inventory and the sequence of charge or discharge when repeating the case.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.