The recorded vol.T temperature spans 9.9019 °C to 25.07 °C in this simulation. That is a change of 15.168 K. The first saved maximum occurs at 44,928 s. The source trace and download retain absolute temperatures in kelvin.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named AirToWater2D_OneRoomRadiator. The source file places it under Fluid, Heat Pumps, Modular Reversible. We used the 101 stored values for vol.T over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name safCtrPar (Wuellhorst2021). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 0 s, vol.T is 293.15 K and temRet.T is 323.15 K. Subtracting the second value from the first gives -30 K. This is their largest recorded absolute separation. A difference between an inlet and an outlet, or between a command and a response, need not be a measurement error.

Air-to-water2 d one room radiator. The simulated vol.T channel runs from 283.052 to 298.22 K over 86,400 seconds.
Air-to-water2 d one room radiator. The simulated vol.T channel runs from 283.052 to 298.22 K over 86,400 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 51,840 to 52,704 seconds. Subtracting 296.703 from 289.305 gives -7.398 K. Its location brackets the change within one saved interval of 864 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

vol.T (K)

temRet.T (K)

0

293.15

323.15

3456

283.0519

295.6329

17280

294.0098

310.9936

34560

289.4996

300.1029

44928

298.2201

299.0012

51840

296.7033

294.3052

52704

289.3049

293.1094

69120

289.4813

301.0359

86400

292.8837

305.5386

What to check on site

Read the evaporator, condenser and electrical channels at the same duty. The water or air temperatures entering the equipment constrain capacity and efficiency. A compressor command does not specify how much heat actually crosses the useful-load boundary.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.