The vol.T trace covers 14.379 to 21.99 °C, a temperature span of 7.611 K. The first recorded maximum occurs at 29,376 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named VCLib4DAirToWater_OneRoomRadiator. The source file places it under Fluid, Heat Pumps, Modular Reversible. We used the 101 stored values for vol.T over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name TAirSouSte (Pulse), sigBusHeaPum (Refrigerant Machine Control Bus), reaPasThr (Real Pass Through). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel temRet.T covers 297.554 to 323.15 K. At 0 s, the primary value is 293.15 and the companion is 323.15. Their signed difference is -30 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Air-to-water heat pump with 4 d data based on vc lib. The simulated vol.T channel runs from 287.529 to 295.14 K over 86,400 seconds.
Air-to-water heat pump with 4 d data based on vc lib. The simulated vol.T channel runs from 287.529 to 295.14 K over 86,400 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 864 to 1,728 seconds. Subtracting 293.035 from 289.614 gives -3.421 K. Its location brackets the change within one saved interval of 864 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

vol.T (K)

temRet.T (K)

0

293.15

323.15

864

293.0345

310.1537

1728

289.6136

304.6397

2592

287.5286

303.9074

17280

293.9616

312.449

29376

295.14

310.5611

34560

292.4684

303.781

51840

291.6517

301.3579

69120

293.5606

308.3181

86400

293.3617

306.7598

What to check on site

Read the evaporator, condenser and electrical channels at the same duty. The water or air temperatures entering the equipment constrain capacity and efficiency. A compressor command does not specify how much heat actually crosses the useful-load boundary.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.