The recorded vol.T temperature spans 16.606 °C to 21.884 °C in this simulation. That is a change of 5.2776 K. The first saved maximum occurs at 30,240 s. The source trace and download retain absolute temperatures in kelvin.

The system being tested

The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named VCLib4DExhaustAirToWater_OneRoomRadiator. The source file places it under Fluid, Heat Pumps, Modular Reversible. We used the 101 stored values for vol.T over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name temOut (Temperature Two Port). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 0 s, vol.T is 293.15 K and temRet.T is 323.15 K. Subtracting the second value from the first gives -30 K. This is their largest recorded absolute separation. A difference between an inlet and an outlet, or between a command and a response, need not be a measurement error.

Air-to-water heat pump with 4 d data based on vc lib for exhaust air heat pump. The simulated vol.T channel runs from 289.756 to 295.034 K over 86,400 seconds.
Air-to-water heat pump with 4 d data based on vc lib for exhaust air heat pump. The simulated vol.T channel runs from 289.756 to 295.034 K over 86,400 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 864 to 1,728 seconds. Subtracting 293.12 from 291.034 gives -2.086 K. Its location brackets the change within one saved interval of 864 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

vol.T (K)

temRet.T (K)

0

293.15

323.15

864

293.1198

309.3934

1728

291.034

305.3481

2592

289.7562

305.6253

17280

293.3813

311.598

30240

295.0339

309.9796

34560

292.4583

305.1325

51840

294.0273

303.8334

69120

293.1484

308.2187

86400

293.3399

307.1013

What to check on site

Read the evaporator, condenser and electrical channels at the same duty. The water or air temperatures entering the equipment constrain capacity and efficiency. A compressor command does not specify how much heat actually crosses the useful-load boundary.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.