The recorded ahu.T_6 channel spans 293.638 to 297.633 source units in this reference run. It starts at 294.223 and ends at 294.22. The first recorded maximum occurs at 32,832 seconds and the first minimum at 76,032 seconds.
The system being tested
The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named AHU. The source file places it under Airflow, Air Handling Unit. We used the 101 stored values for ahu.T_6 over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.
The reference file contains 20 recorded variables. Alongside the primary output there are ahu.allCond, ahu.startState.active, ahu.deHuHRS_true.active, ahu.deHuHRS_false.active, ahu.onlyHeatingHRS_true.active. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.
Compare the recorded channels
The companion channel ahu.T_oda covers 282 to 302 source units. At 2,592 s, the primary value is 294.509 and the companion is 282.173. Their signed difference is 12.336 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 53,568 to 54,432 seconds. Subtracting 295.703 from 295.577 gives -0.1255 source units. Its location brackets the change within one saved interval of 864 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | ahu.T_6 (source units) | ahu.T_oda (source units) |
|---|---|---|
0 | 294.2228 | 282 |
17280 | 296.5388 | 288.8895 |
32832 | 297.6326 | 299.2751 |
34560 | 297.6096 | 300.0776 |
51840 | 295.9524 | 300.1027 |
53568 | 295.7027 | 299.3043 |
54432 | 295.5772 | 298.861 |
69120 | 293.8573 | 288.9301 |
76032 | 293.6384 | 284.7249 |
86400 | 294.2198 | 282 |
What to check on site
Identify the connected zones, pressure references and flow direction. Changing a door, leakage path or boundary condition can redistribute the same total flow between branches. A differential pressure alone cannot establish the air quantity reaching a zone.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.