The recorded ac.TIn temperature spans 19.857 °C to 39.849 °C in this simulation. That is a change of 19.992 K. The first saved maximum occurs at 252 s. The source trace and download retain absolute temperatures in kelvin.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named Ren2014ACBedroom. The source file places it under Occupants, Residential, Air Conditioning. We used the 101 stored values for ac.TIn over the interval 0 to 3,600 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name occ (Boolean Step), Tin (Sine), ac (Ren2014 AC Bedroom). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 2,016 s, ac.TIn reads 304.004 K and ac.on reads 0. Across the run, the second channel ranges from 0 to 1. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Air conditioning AC behaviors. The simulated ac.TIn channel runs from 293.007 to 312.999 K over 3,600 seconds.
Air conditioning AC behaviors. The simulated ac.TIn channel runs from 293.007 to 312.999 K over 3,600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 1,980 to 2,016 seconds. Subtracting 301.747 from 304.004 gives 2.257 K. Its location brackets the change within one saved interval of 36 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

ac.TIn (K)

ac.on (logical state)

0

303

0

252

312.9992

0

720

293.1771

0

756

293.0071

0

1440

306.6812

1

1980

301.7467

0

2016

304.0036

0

2160

311.4433

1

2880

296.1545

0

3600

297.1222

1

What to check on site

Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Units in the source model

The component declarations identify the scale of the exported variables. In this run, ac.on uses logical state. Keep the exact channel name and unit together when exporting data to a historian. Read the component definition.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.