The signed flow trace gives a net 43,886.4 kg over 86,400 s, using the trapezoidal rule between saved samples. The smallest and largest reported rates are -5.189e-09 kg/s and 1.2084 kg/s. Check the positive flow direction in the model before using the sign to describe delivery or return.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named AirHeating. The source file places it under Thermal Zones, Energy Plus 24 2 0, Single Family House. We used the 101 stored values for hea.m_flow over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name zon (Thermal Zone), fan (Flow Controlled m flow), TSet (Pulse), conPID (PID). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 86,400 s, hea.m_flow reads 0.60418 kg/s and conPID.y reads 0.052696. Across the run, the second channel ranges from 0 to 1. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Air-based heating system that conditions a thermal zone in energy plus. The simulated hea.m_flow channel runs from -5.19e-09 to 1.208 kg/s over 86,400 seconds.
Air-based heating system that conditions a thermal zone in energy plus. The simulated hea.m_flow channel runs from -5.19e-09 to 1.208 kg/s over 86,400 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed rate over 86,400 seconds gives a net 43,886 kg. This estimate averages neighbouring stored rates and multiplies by their time separation. Reverse flow reduces the net total. If a process requires gross throughput, calculate forward and reverse transfers separately at the appropriate boundary.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

hea.m_flow (kg/s)

conPID.y (source units)

0

0

0

17280

0.604184

0.1379676

22464

1.208368

1

34560

0.604184

0.3732985

51840

0.604184

0.1502928

69120

0

0

77760

-5.188987e-09

0.1135519

85536

0

0.3036418

86400

0.604184

0.05269568

What to check on site

Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.