The recorded agePumCon.y channel spans 0 to 0.5 source units in this reference run. It starts at 0 and ends at 0. The first recorded maximum occurs at 900 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named AgentPump1PipeExample. The source file places it under DHC, Networks, Controls. We used the 101 stored values for agePumCon.y over the interval 0 to 3,600 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name agePumCon (Agent Pump1 Pipe), con2 (Constant), TPlaSup (Constant). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel agePumCon.TSouIn starts at 283.15, ends at 283.15 and has a recorded range of 280.15 to 286.15 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Agent pump1 pipe. The simulated agePumCon.y channel runs from 0 to 0.5 source units over 3,600 seconds.
Agent pump1 pipe. The simulated agePumCon.y channel runs from 0 to 0.5 source units over 3,600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 720 to 756 seconds. Subtracting 0 from 0.34 gives 0.34 source units. Its location brackets the change within one saved interval of 36 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

agePumCon.y (source units)

agePumCon.TSouIn (source units)

0

0

283.15

720

0

285.55

756

0.34

285.67

900

0.5

286.15

1440

0

284.35

2160

0

281.95

2880

0.3

280.75

3600

0

283.15

What to check on site

Mark the measurement points on a hydraulic schematic and identify whether the controller holds flow or differential pressure. Record pump command and delivered duty together. A site comparison needs the same branch state, including bypasses and closed valves.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.