The TOut.T trace covers 0.1712 to 20 °C, a temperature span of 19.829 K. The first recorded maximum occurs at 0 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named Discharging2. The source file places it under Fluid, Storage, Ice, Experiment NIST. We used the 101 stored values for TOut.T over the interval 0 to 36,890 seconds. This is a simulated test with specified inputs and boundaries.
The reference file contains 8 recorded variables. Alongside the primary output there are dat.y[1], TIn.Celsius, dat.y[2], TOut.T, dat.y[3]. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.
Compare the recorded channels
The companion channel dat.y[2] starts at 0.05556, ends at 2.667 and has a recorded range of 0.05556 to 2.667 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 0 to 368.9 seconds. Subtracting 293.15 from 273.321 gives -19.829 K. Its location brackets the change within one saved interval of 368.9 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | TOut.T (K) | dat.y[2] (source units) |
|---|---|---|
0 | 293.15 | 0.05555556 |
368.9 | 273.3212 | 0.1111111 |
7378 | 273.636 | 0.5555556 |
14756 | 274.1604 | 0.8888889 |
22134 | 274.8566 | 1.388889 |
29512 | 275.5487 | 1.944444 |
36890 | 276.2903 | 2.666667 |
What to check on site
Identify the stored quantity and the boundary through which energy or mass enters. A layer temperature, outlet temperature and volume mean describe different states. Preserve initial inventory and the sequence of charge or discharge when repeating the case.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.