The archived response ranges from 35.23 to 83.25. The median is 66.55 and the central half of the measurements extends from 61.39 to 71.54. Those figures use all 125 numeric observations in this source series and retain its original measurement scale.

What was measured

The REESE data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as strength. It preserves the source scale and its sign. The file contains 1 numeric field per accepted row.

Spread across the original readings

The tenth percentile is 56.838 and the ninetieth is 75.85. They provide a narrower description of the typical spread than the minimum and maximum. The largest and smallest observed records are separated by 48.02. This is the range of this sample, rather than a guaranteed operating envelope.

Aerospace composite strength measurements. The 25th, 50th and 75th percentiles of the measurements are 61.39, 66.55 and 71.54.
Aerospace composite strength measurements. The 25th, 50th and 75th percentiles of the measurements are 61.39, 66.55 and 71.54. Figure by Industry Applied.

One row you can check

To check a real observation, take numeric row 36 after the header. Its response is 66.55. The overall arithmetic mean is 65.834, so this observation is 0.716 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 10.15, calculated by subtracting 61.39 from 71.54.

The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.

Worked data

Percentile

Observed response (source scale)

Number of numeric rows

0

35.23

125

10

56.838

125

25

61.39

125

50

66.55

125

75

71.54

125

90

75.85

125

100

83.25

125

Implications for an industrial comparison

Compare the specimen geometry, preparation, loading direction, conditioning and endpoint before using this distribution in a materials decision. Failure observations from a controlled test do not directly provide a field failure probability. A comparison with current production also needs the number of specimens withdrawn before the stated endpoint.

Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.

Source file and worked data

The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.