The recorded act_1.y channel spans 0 to 1 source units in this reference run. It starts at 0 and ends at 1. The first recorded maximum occurs at 20 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named ActuatorFilter. The source file places it under Fluid. We used the 101 stored values for act_1.y over the interval 0 to 20 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name act_1 (Actuator Filter), act_2 (Actuator Filter), gain (Gain), act_y_start05 (Actuator Filter). The source declares riseTime = 10. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel act_2.y covers 0 to 99.999 source units. At 20 s, the primary value is 1 and the companion is 99.999. Their signed difference is -98.999 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Actuator filter. The simulated act_1.y channel runs from 0 to 1 source units over 20 seconds.
Actuator filter. The simulated act_1.y channel runs from 0 to 1 source units over 20 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 1.2 to 1.4 seconds. Subtracting 0.2393 from 0.2964 gives 0.0571 source units. Its location brackets the change within one saved interval of 0.2 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

act_1.y (source units)

act_2.y (source units)

0

0

0

1.2

0.239343

23.9343

1.4

0.2964441

29.64441

4

0.8163508

81.63508

8

0.9855761

98.55761

12

0.999076

99.9076

16

0.9999453

99.99453

20

0.9999931

99.99931

What to check on site

Distinguish the component characteristic from the installed system response. Record the pressure or temperature on both sides as applicable, the direction of flow and the actuator command. Compare a change at constant demand with one caused by a different load.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.