The recorded actAirSet.uOpeMod channel spans 1 to 6 source units in this reference run. It starts at 1 and ends at 6. The first recorded maximum occurs at 3,276 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named ActiveAirFlow. The source file places it under Controls, OBC, ASHRAE, G36, Terminal Units, Dual Duct Cold Duct Min, Subsequences. We used the 101 stored values for actAirSet.uOpeMod over the interval 0 to 3,600 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name actAirSet (Active Air Flow), minFlo (Sin), opeMod (Ramp), reaToInt2 (Real To Integer). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel actAirSet.VActMin_flow covers 0 to 0.3763 source units. At 3,276 s, the primary value is 6 and the companion is 0. Their signed difference is 6 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Active air flow. The simulated actAirSet.uOpeMod channel runs from 1 to 6 source units over 3,600 seconds.
Active air flow. The simulated actAirSet.uOpeMod channel runs from 1 to 6 source units over 3,600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 360 to 396 seconds. Subtracting 1 from 2 gives 1 source units. Its location brackets the change within one saved interval of 36 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

actAirSet.uOpeMod (source units)

actAirSet.VActMin_flow (source units)

0

1

0.2

360

1

0.3763356

396

2

0

720

2

0

1440

3

0

2160

4

0

2880

5

0

3276

6

0

3600

6

0

What to check on site

Separate a calculated setpoint from the damper or fan command and from the measured service delivered. Trend the active operating mode, request, actual flow and zone condition on one clock. A sequence can change state correctly while the terminal fails to reach duty.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.