The masAcc.mCon trace ranges from 0 kg to 1.0019 kg across 101 saved checkpoints. It begins at 0 kg and finishes at 0.38438 kg after 63,072,000 s of test time. The source identifies the channel scale as kg. Its first saved maximum occurs at 46,042,560 s.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named MassAccumulation. The source file places it under Fluid, Air Filters. We used the 101 stored values for masAcc.mCon over the interval 0 to 63,072,000 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name masAcc (Mass Accumulation), repFil (True Delay). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
At 30,274,560 s, masAcc.mCon reads 0.020179 kg and masAcc.mCon_flow[1] reads 5.259e-08 kg/s. Across the run, the second channel ranges from 1.547e-08 kg/s to 9.281e-08 kg/s. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.
Reproduce the calculation
The largest absolute change between consecutive stored points appears from 29,643,840 to 30,274,560 seconds. Subtracting 0.9973 from 0.02018 gives -0.9771 source units. Its location brackets the change within one saved interval of 630,720 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | masAcc.mCon (kg) | masAcc.mCon_flow[1] (kg/s) |
|---|---|---|
0 | 0 | 1.54679e-08 |
1.26144e+07 | 0.2926779 | 3.093581e-08 |
2.52288e+07 | 0.7804738 | 4.640371e-08 |
2.964384e+07 | 0.997299 | 5.181748e-08 |
3.027456e+07 | 0.02017852 | 5.259087e-08 |
3.78432e+07 | 0.4533414 | 6.187162e-08 |
4.604256e+07 | 1.001868 | 7.192575e-08 |
5.04576e+07 | 0.3213094 | 7.733952e-08 |
6.3072e+07 | 0.3843818 | 9.280743e-08 |
What to check on site
Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Units in the source model
The component declarations identify the scale of the exported variables. In this run, masAcc.mCon uses kg and masAcc.mCon_flow[1] uses kg/s. Keep the exact channel name and unit together when exporting data to a historian. Read the component definition.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.