The recorded winAbs.QAbsIntSha_flow[1] channel spans 2.641 to 162.784 source units in this reference run. It starts at 2.641 and ends at 2.641. The first recorded maximum occurs at 561,600 seconds and the first minimum at 0 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named AbsorbedRadiation. The source file places it under Heat Transfer, Windows. We used the 101 stored values for winAbs.QAbsIntSha_flow[1] over the interval 0 to 864,000 seconds. This is a simulated test with specified inputs and boundaries.
The source declares azi = 0, til = 1.5707963267949. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The primary channel spends 13.9% of its saved checkpoints at or above 82.713 source units, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 24.213 source units. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.
![Absorbed radiation by windows. The simulated winAbs.QAbsIntSha_flow[1] channel runs from 2.641 to 162.784 source units over 864,000 seconds.](https://static.wixstatic.com/media/21e41b_4597897e9904404fb281f3b498b571a4~mv2.png/v1/fill/w_616,h_345,al_c,q_85,enc_auto/21e41b_4597897e9904404fb281f3b498b571a4~mv2.png)
Reproduce the calculation
The largest absolute change between consecutive stored points appears from 544,320 to 552,960 seconds. Subtracting 10.771 from 124.617 gives 113.847 source units. Its location brackets the change within one saved interval of 8,640 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | winAbs.QAbsIntSha_flow[1] (source units) |
|---|---|
0 | 2.64148 |
172800 | 2.64148 |
345600 | 2.64148 |
518400 | 2.64148 |
544320 | 10.77068 |
552960 | 124.6174 |
561600 | 162.7839 |
691200 | 2.64148 |
864000 | 2.64148 |
What to check on site
Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.