How complete is a day of five-minute sensor data?
Count unique expected observation slots, duplicates and coverage gaps before using a sensor average in an operating report.

A treatment plant receives 288 messages from a five-minute logger in a 24-hour UTC day. The total looks perfect until a technician notices four repeated timestamps. Counting deliveries alone can hide gaps that affect daily averages, maxima or environmental reports.
Build the expected time grid
Define the period, its time zone, cadence and treatment of its end boundary. For a regular five-minute device, use a half-open interval from the start up to, but excluding, the next day. Assign each accepted observation to one slot using a documented tolerance. Keep duplicates, late arrivals and invalid readings in separate counts.
In an illustrative 24-hour day, 24 × 60 ÷ 5 gives 288 expected slots. The receiver logs 288 arrivals, including four duplicates, with 284 distinct valid slots. Completeness is 284 ÷ 288 = 98.6%. The four missing slots could be isolated, or could form one continuous 20-minute gap.

What to check on site
Report the longest consecutive gap as well as the percentage complete.
Keep the timestamp convention and late-arrival cutoff with the published figure.
Recalculate a daily aggregate when an accepted backfill changes coverage.
An Australian water operator comparing against a public weather feed should also check the feed’s own quality flags. A high completeness percentage can still hide the one interval containing the day’s peak.
Sources and photograph
OGC — SensorThings API, sensing specification
Bureau of Meteorology — latest observations
A treatment plant receives 288 messages from a five-minute logger in a 24-hour UTC day. The total looks perfect until a technician notices four repeated timestamps. Counting deliveries alone can hide gaps that affect daily averages, maxima or environmental reports.
Build the expected time grid
Define the period, its time zone, cadence and treatment of its end boundary. For a regular five-minute device, use a half-open interval from the start up to, but excluding, the next day. Assign each accepted observation to one slot using a documented tolerance. Keep duplicates, late arrivals and invalid readings in separate counts.
In an illustrative 24-hour day, 24 × 60 ÷ 5 gives 288 expected slots. The receiver logs 288 arrivals, including four duplicates, with 284 distinct valid slots. Completeness is 284 ÷ 288 = 98.6%. The four missing slots could be isolated, or could form one continuous 20-minute gap.

What to check on site
Report the longest consecutive gap as well as the percentage complete.
Keep the timestamp convention and late-arrival cutoff with the published figure.
Recalculate a daily aggregate when an accepted backfill changes coverage.
An Australian water operator comparing against a public weather feed should also check the feed’s own quality flags. A high completeness percentage can still hide the one interval containing the day’s peak.