Industrial IoT · Manufacturing
What a coolroom door spike tells you about the food
An air logger responds to a doorway draught differently from a product probe. Plan a comparison that gives each measurement a clear purpose.

The air logger by a loading door records a short temperature spike during dispatch. An operator asks whether every carton warmed by the same amount. Air and product have different thermal responses. A single air value cannot settle a product-release decision.
Pair the measurement with the question
To study door recovery, record air at a known location and the door-open event. To assess a product, follow the site’s food-safety plan and the appropriate measurement method for the product and location. A buffered probe can help characterise a slower response when its purpose and limitations have been documented. Identify each probe clearly on the graph.
In an illustrative trial, air reads 3 °C before loading, 9 °C at the end of a door opening and 4 °C ten minutes later. A separate reference load reads 3.0, 3.4 and 3.3 °C at those times. These numbers describe the two test sensors. They cannot establish the temperatures of other packs or prove the lot suitable for release.

What to check on site
Record sensor position, response time and reference checks.
Note pallet position, packaging and loading pattern with the trace.
Use the site’s approved product assessment whenever a release decision is required.
FSANZ and New Zealand Food Safety publish guidance for checking food temperatures. Use the local requirements and site procedure to decide which measurement belongs in the product record.
Sources and photograph
Food Standards Australia New Zealand — thermometers
The air logger by a loading door records a short temperature spike during dispatch. An operator asks whether every carton warmed by the same amount. Air and product have different thermal responses. A single air value cannot settle a product-release decision.
Pair the measurement with the question
To study door recovery, record air at a known location and the door-open event. To assess a product, follow the site’s food-safety plan and the appropriate measurement method for the product and location. A buffered probe can help characterise a slower response when its purpose and limitations have been documented. Identify each probe clearly on the graph.
In an illustrative trial, air reads 3 °C before loading, 9 °C at the end of a door opening and 4 °C ten minutes later. A separate reference load reads 3.0, 3.4 and 3.3 °C at those times. These numbers describe the two test sensors. They cannot establish the temperatures of other packs or prove the lot suitable for release.

What to check on site
Record sensor position, response time and reference checks.
Note pallet position, packaging and loading pattern with the trace.
Use the site’s approved product assessment whenever a release decision is required.
FSANZ and New Zealand Food Safety publish guidance for checking food temperatures. Use the local requirements and site procedure to decide which measurement belongs in the product record.
Sources and photograph
Food Standards Australia New Zealand — thermometers