Manufacturing
Put a heat value on returned condensate
A first-pass energy balance helps a boiler team decide which condensate streams deserve measurement. Temperature and mass flow both matter.

A food processor has an accessible condensate return record and a make-up water meter. Before commissioning a recovery study, the engineering team wants the order of magnitude of the heat already carried by the hot water. A simple sensible-heat calculation can answer that narrow question.
Set the reference at the incoming water
Measure the mass of liquid returned and its temperature where it crosses the chosen boundary. Use the make-up water temperature measured over the same period. Keep flash steam, losses along the return line and boiler efficiency outside this first calculation. Their effects can be added when the recovery proposal is better defined.
In an illustrative shift, 2,000 kg of liquid returns at 80 °C while incoming water is at 20 °C. With a water heat capacity of 4.18 kJ/(kg·K), the available difference is 2,000 × 4.18 × 60 = 501,600 kJ, or about 139 kWh of thermal energy.

What to check on site
Note whether a reported flow is liquid mass, liquid volume or a mixed stream.
Record return temperatures at the point where the plant could use the heat.
Check water-quality acceptance and operating hours with the boiler and process teams.
An Australian dairy or a New Zealand beverage plant can use this estimate to choose a metering point. Valuing fuel displacement requires the actual alternative heat source, operating efficiency and coincidence with demand.
Sources and photograph
Australian Government — process heat and steam
A food processor has an accessible condensate return record and a make-up water meter. Before commissioning a recovery study, the engineering team wants the order of magnitude of the heat already carried by the hot water. A simple sensible-heat calculation can answer that narrow question.
Set the reference at the incoming water
Measure the mass of liquid returned and its temperature where it crosses the chosen boundary. Use the make-up water temperature measured over the same period. Keep flash steam, losses along the return line and boiler efficiency outside this first calculation. Their effects can be added when the recovery proposal is better defined.
In an illustrative shift, 2,000 kg of liquid returns at 80 °C while incoming water is at 20 °C. With a water heat capacity of 4.18 kJ/(kg·K), the available difference is 2,000 × 4.18 × 60 = 501,600 kJ, or about 139 kWh of thermal energy.

What to check on site
Note whether a reported flow is liquid mass, liquid volume or a mixed stream.
Record return temperatures at the point where the plant could use the heat.
Check water-quality acceptance and operating hours with the boiler and process teams.
An Australian dairy or a New Zealand beverage plant can use this estimate to choose a metering point. Valuing fuel displacement requires the actual alternative heat source, operating efficiency and coincidence with demand.
Sources and photograph
Australian Government — process heat and steam