What the driest catch cans tell you about a sprinkler run
Use the lowest quarter of catch-can depths to see whether the average hides a dry strip across a block.

A sprinkler run averages 10 mm across a paddock. The crop still shows a pale strip at one end. An average cannot reveal whether the water was spread evenly. A catch-can test puts a spatial pattern and a number behind the observation.
Keep each can on the map
Use comparable collectors and record their positions, run duration, pressure, wind and sprinkler settings. Follow a layout suitable for the irrigation system. Seek advice on weighting where collectors represent unequal areas, particularly under a centre pivot. The small example below assumes equally weighted positions.
Eight collectors, ordered by depth, hold 6, 8, 9, 10, 10, 11, 12 and 14 mm. Their mean is 10 mm. The lowest quarter contains two collectors, averaging 7 mm. Low-quarter distribution uniformity is 7 ÷ 10 × 100 = 70%. Return those two low values to their positions on the field map.

What to check on site
Check whether both low results sit downwind, at an edge or near one nozzle.
Repeat under comparable conditions after addressing a suspected cause.
Record average applied depth and distribution uniformity as separate results.
A Canterbury irrigator or Riverina grower can use the numbered-can map to choose what to inspect. Extending runtime to cover the dry strip also increases application over the already wet positions.
Sources and photograph
NSW Local Land Services — testing irrigation efficiency
Irrigation Association — factors affecting catch-can results
A sprinkler run averages 10 mm across a paddock. The crop still shows a pale strip at one end. An average cannot reveal whether the water was spread evenly. A catch-can test puts a spatial pattern and a number behind the observation.
Keep each can on the map
Use comparable collectors and record their positions, run duration, pressure, wind and sprinkler settings. Follow a layout suitable for the irrigation system. Seek advice on weighting where collectors represent unequal areas, particularly under a centre pivot. The small example below assumes equally weighted positions.
Eight collectors, ordered by depth, hold 6, 8, 9, 10, 10, 11, 12 and 14 mm. Their mean is 10 mm. The lowest quarter contains two collectors, averaging 7 mm. Low-quarter distribution uniformity is 7 ÷ 10 × 100 = 70%. Return those two low values to their positions on the field map.

What to check on site
Check whether both low results sit downwind, at an edge or near one nozzle.
Repeat under comparable conditions after addressing a suspected cause.
Record average applied depth and distribution uniformity as separate results.
A Canterbury irrigator or Riverina grower can use the numbered-can map to choose what to inspect. Extending runtime to cover the dry strip also increases application over the already wet positions.
Sources and photograph
NSW Local Land Services — testing irrigation efficiency
Irrigation Association — factors affecting catch-can results